Skip to main content
Specifications
HPA Power Level:
- ATSC up to 30 kW average per HPA, tube dependent
- DVB‐T up to 20 kW average per HPA, tube dependent
- For system output refer to General Transmitter Description (GTD)
Operating Frequency:
- UHF (470‐810/860 MHz)
- Settings in 1 Hz steps, standard
Frequency Stability:
- ± 1 Hz with ext. 10 MHz reference
- ± 100 Hz 30 days (int. reference)
Adjacent Channel Shoulders:
- ATSC better than ‐47 dB before FCC
mask filtering (first 500 kHz relative to 6
MHz channel)
- DVB‐T 35 dB shoulders min
- Harmonics 110 dB below reference
ATSC In‐Band Signal‐to‐Noise:
- Better than 27 dB or 4.0% EVM
DVB‐T Modulation Error Ratio:
Connector:
- 50Ω standard EIA or waveguide
Mains Power:
- 480 VAC (+9/‐15%), 3‐phase, 4 wire (WYE)
plus ground
- Frequency: 48‐62 Hz
- Consumption/Efficiency:
- Power‐level dependent, consult your
sales representative
- > 0.9 Power Factor (PF)
Physical/Environmental Conditions:
- 0° to 45℃ Temp range (24℃ ±10℃ recommended)
- ≤ 90% non‐condensing relative humidity
- Altitude: 2,000 meters
- Access safety: IEC 215 compliant